Leak or condensation?
The two look alike from below, so it is worth knowing the differences. A leak is usually in one spot, appears during or after rain, and often sits near a chimney, valley or damaged tile. Condensation is spread out. It tends to be worst on cold, still mornings, shows as droplets or frost on the underside of the felt or membrane, and leaves mould across rafters and boards. Some lofts have both, which is why we check before recommending anything. Adding vents will not cure a slipped tile, and new tiles will not cure condensation.
Why lofts get condensation
Every home produces moisture from cooking, showers, drying washing and breathing. Some of that warm, damp air rises into the loft through gaps around the hatch, downlights, pipes and cables. In a cold loft above thick insulation, the roof timbers and underlay are much colder than the air, so moisture condenses on them. Common triggers include:
- A new non-breathable underlay with no added ventilation, often after a re-roof
- Insulation pushed into the eaves, blocking the airflow that used to come in there
- Extractor fans or a tumble dryer venting into the loft instead of outside
- An unsealed loft hatch, or recessed lights cut through the ceiling
- Uninsulated water tanks and pipes with cold surfaces
How we ventilate a roof
The aim is a steady flow of outside air through the roof space, usually in low at the eaves and out high near the ridge. The right mix depends on the roof shape, its pitch, the underlay and how the loft is insulated.
Low-level ventilation
- Soffit vents. Strip or circular vents in the soffit boards under the eaves.
- Over-fascia vents. A vent strip on top of the fascia board, under the bottom row of tiles. These are often fitted when fascias and soffits are replaced, as on our fascia and soffit replacement work.
- Eaves trays and rafter vents. Rigid trays support the underlay at the eaves and stop insulation blocking the air path.
High-level ventilation
- Tile and slate vents. Purpose-made vents swapped in for a tile or slate near the ridge, matched to the roof covering.
- Ventilated dry ridge. A mechanically fixed ridge system with a vented gap, often fitted when the ridge needs attention anyway. See our ridge and hip tile work.
How much ventilation?
The industry standard is BS 5250, and manufacturers follow it in their guidance. As a broad example, a traditional cold roof with a non-breathable underlay typically needs eaves ventilation equal to a continuous 10 mm gap, or 25 mm on shallow pitches of 15 degrees or less, and steeper or wider roofs may also need a 5 mm opening at the ridge. Breathable membranes can reduce the requirement, but only in the right conditions. We work out what your roof needs rather than adding vents at random.
Bats and older roofs
Many Somerset farmhouses and cottages have bats in the roof. Bats and their roosts are protected, and Natural England guidance says work on roofs and lofts may need a bat survey and possibly a licence. The Bat Conservation Trust also advises against using breathable membranes where bats roost, because bats can get tangled in the fibres; bitumen felt is used instead, with ventilation provided separately. If you know or suspect bats, tell us at the start.
Cutting moisture at the source
Ventilation works best alongside a few simple steps inside the house:
- Make sure bathroom and kitchen fans vent outside, not into the loft
- Fit a draught-sealed, insulated loft hatch
- Keep insulation back from the eaves so air can flow
- Insulate water tanks and pipes, but don't put insulation under a tank
How the job runs
We start in the loft, looking at where the damp is, the underlay, the insulation at the eaves and any fans or ducts. You get photos and a written explanation of the likely cause. Most vents can be fitted from outside without disturbing much of the roof. If mould has stained the timbers, we will tell you whether any are damaged or whether it is surface staining that will stop once the roof dries.
There is no call-out fee, and the quote is free and written down. Describe what you have seen in the loft and when, and book a loft condensation check.
Roof Ventilation: common questions
Why is my loft wet when the roof isn't leaking?
Usually condensation. Warm, moist air from the house rises into the loft and condenses on the cold underside of the felt or membrane and the roof timbers. It is often worst on cold, clear mornings and can drip onto insulation, looking just like a leak. Blocked eaves, a sealed-up roof after re-roofing, or fans venting into the loft are common causes.
Will more loft insulation cause condensation?
It can if it is laid badly. Thicker insulation keeps the loft colder, which is normal, but if it is pushed into the eaves it blocks the air that should flow in there. Keep insulation back from the eaves, or fit eaves trays or rafter vents, and seal gaps around the loft hatch and pipes. Done properly, good insulation and good ventilation work together.
Does mould in the loft mean the timbers are rotten?
Not necessarily. Black mould on rafters and boarding is often only surface staining that stops once the roof space dries out. Rot is different: the timber goes soft, cracked or crumbly. We check with a probe where we see staining, and we tell you whether timbers need treatment or replacing or just need the cause sorting.
Can you add ventilation without re-roofing?
Yes, in most cases. Soffit or over-fascia vents can be fitted at the eaves, and tile or slate vents can be swapped in near the ridge without stripping the roof. A ventilated dry ridge is a good option if the ridge tiles need rebedding anyway. Whole re-roofing is only needed if the roof is due for replacement for other reasons.
Is a breathable membrane enough on its own?
Not always. Breathable membranes let some vapour through, which can reduce the ventilation needed, but manufacturers and BS 5250 still call for ventilation in many situations, depending on the ceiling, the roof covering and the membrane itself. In roofs with bats, the Bat Conservation Trust advises against these membranes altogether, so the roof is ventilated in other ways.